But, you know whats not great? They can also fail if used on a salt pool (there are salt seals that can be used), or if the motor and shaft heats up to high temps. Checked to make sure nothing was blocking it. Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. Check the wiring in the back of the motor, is the cord firmly attached? Well, the good news is you are at the right spot and youre definitely not alone. Getting air in basket, changed gasket with lube still have the same issue. Inspect the motor shaft for any obstructions. Hi Jim, bummer! Can it be repaired or do we need a new pump? Checked breakers etc tried again and it came onbut very loud. Trying not to damage impeller. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. So, I dont think you can use this motor, (sorry), unless you are able to add another 110V wire, and run both connected wires from a Double pole breaker. The breaker is probably overloaded. Thanks in advance for any help you can provide, the pool should be done in the next few days and need to figure out this pump situation. Are you using DE powder or enough DE powder? Should have the hard plastic side facing the motor and the soft rubber side facing the impeller. It feels like its not doing what its supposed to do. Soak in TSP for an hour, and in the acid for 10 minutes. The correct lateral assy for the S210 filter would be the SX210DA if you used a smaller assy, the pipe wont reach all the way into (inside of) the multiport valve base, and allow sand to enter the pipe but just a theory, you likely used the correct and full height SX210DA? It is not just the connection that is leaking, the pump body itself has sprung at least one leak near the neck of the top fitting. Im very new to pools & pool maintenance in general. To rule out the filter, if you have a multiport valve, run the pump on the Waste or Recirculate position. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. Have a Hayward variable that was replaced last year. I checked the breaker and plug connection and they were fine. If communication between the ignition board and the display board is not established within 3 s of power-up an error will be displayed. Now if it really is your pump, and not the heater making this noise, that I cant explain, must be the heater? I recently noticed what appears to be a shaft seal leak. it continues to cycle this way. No lights are coming on as if no power. Maybe the GFCI button tripped? Davy, Turned it off and then tried it again and it hummed for a few and the something glowed red and then stopped humming. The 1.5 hp pump was so strong you couldnt stand in front of the single return, which is why I used smaller pump. "width": "611",
Not normal, but cant see a reason why that would cause the seal to fail. I dont really know if my pump can be repaired or if the only solution is buying a new pump so soon. Hi Tim, If Assy A has a bad motor (test it? This past week the motor sometimes starts sometimes does not sometimes starts and turns itself off. Pool pump already went out a few months ago. Checked to see that there was no short in the wire with an ohms meter . I would start by lubing the pump lid o-ring with pool lube, and trying to tighten the lid a bit more if you can. No lubricant is needed for spider gaskets. If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . Also will need to have clean pump basket and a clean pool filter, to ensure adequate flow rates. 8. check power at the motor, with a multimeter set on 240V+ place test probes on the brass screws or terminals where the two power wires connect. Lube should not be the issue with the leak, not required. It looks like no one has them in Stock and if I cant filter the pool, then it wont be usable. The previous owners winterized the pump and pool but left all the water in the pool so its full and nasty. John, according to the manual, CEL is the code for Panel not receiving data from control. If no power at motor, check connections for tightness, inspect wire and conduit for damage. Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. "keywords": "hayward pool pump",
RPS. Product Type Model Name Select Model # I completely back washed and clean the system two times making sure the filter was put together properly and there were no holes in either the manifold or the filter grids. Hi you are getting power inside the motor, on the terminal board? The original pump (assy A) smells burnt. Hi Martha, open the air bleeder, perhaps there is a lot of air in the tank, drawn in by the pump. A jammed impeller or blown capacitor can lead to a tripped breaker. Suggestions on what to do next. If the impeller wont spin, this is likely the problem. Maybe you could just wire the pump directly to the breaker? They dont typically make noise for long either, because at 3400 RPM, if the impeller is hitting something, it will quickly wear it down. I have a max-flo vs pump and it cant seem to stay at a high rpm for any long stretch of time when its sunny. "dateModified": "05/20/2022",
Please note: The majority of our literature and brochures are in English only. Then I saw a HS code. Step 3: Double check the wires on the flow switch for damage. Incorrect sizing can cause multiple problems, including low water flow. i have a 4 wire set up, ground, line , low speed,high , just want to make sure i wire correctly, 1- line 1, 2- high speed, 3or4 to low speed? GFCIs are sensitive, but for a reason. I put a new power cord socket in the water proof box, which feeds power to the pump, I shined up the power cord plug pins), (power cord is about 2.5 ft of 12 Ga, not wet, not laying on the ground) I dont want to pay someone to come out & charge me more for not knowing what Im doing. 2. pump lid No noise, nothing. Hope that helps! But dont bypass GFCI protection, thats just to determine if its a motor problem or outlet problem. For more info, see page 36 of the Hayward heater owners manual. Anyone else have a scientific explanation? Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE then back to AUTO. So, it could be a problem with the cord, or the connection on the other end of the cord, likely if the motor is making no noise at all. Happens all the time to pool pumps, and the way to un-stick it is to do some disassembly in the rear of the motor, to get a wrench on the slotted rear of the motor shaft, and work the shaft back and forth for a minute, to break the rust seal, and get the shaft to turn again. Hi Steven, probably the breaker tripped or the GFCI test button popped out due to some water touching some wire. I backwash and rinse and start again but it does the same thing. Hi John, do you mean the filter top pops off? The second thing that can cause such a problem is if the pump is starved for water, cavitating, because it is too large (hp) for the piping system, or because incoming valves are closed, or pipes are plugged, or clogged. If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. I did find the black power wire lose on the pump when checking the wire connections, so I reconnected it but to no avail. Next, check continuity from lead to lead. If thats not the problem, try soaking the fingers again, with a stronger solution, and/or leaving them soaking longer. But now Im trying to plug it in and it doesnt make any noise at all. Still nothing. If it makes no noise at all, check that the GFCI test button is not tripped, and flip the circuit breaker off and back on. When corrected, control will run blower for 5 s then automatically restart after 2 minutes. 5. very dirty pool filter, Every time the pump is turned on with the timer it trips the circuit breaker. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. If power is reaching the motor, but nothing (no noise), look for any disconnected or severed wires in the back (shut off power first), if nothing, the motor may be dead. Im having an air leak problem with my pool. Common Salt Chlorine Generator Problems - Pool Research If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. When I then switch the pump breaker off and then back on again it springs into life (every time). Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. Hi Jack, according to the manual, the Drive Error Pump is Stalled error usually refers to water or moisture on the circuit board, under the display panel. Wait for the relay to click (5 to 10 seconds). Could this be my problem? Fitness View More. "address": "",
Is it likely to be the pump or the AutoChlor switches and timer (which I replaced last year)? Also check that water level is good in pool, and skimmer weir is not blocking water flow. Should I worry? No matter what setting I put it in its backwashing the sand into the skimmer. Improper voltage wiring is the usual culprit for smoking pump motors. If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. Cleaners, Learn About Chapter 1: The Evil Emperor's Son. Thanks. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. Can I replace a specific part or do I have to buy a new one? Hmmm, now if the breaker were stopping the power from flowing to the switch, the timeclock would lose time, and would not turn itself on. The motor can be tested briefly without being bolted onto the pump. My salt water pool was shut down for the winter. We are trying to switch the jumper or selector plug (not sure what its called) from 230 to 115 but the jumper doesnt seem to fit smoothly on the 115 setting the prongs it has to slide over seem too far apart and Im afraid of breaking it. Damaged or inadequate wiring, resulting in a power drop, are likely to blame for your Hayward pool pump shutting off. Hayward Tristar VS manual https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true has some good troubleshooting tips. We hope these charts help solve your Hayward pool heater problems. If it is still making chlorine and no real faults are flashing on the control, I wouldnt be too worried about it. Nothing your husband did, hes safe to come out of the doghouse, lol. Will be using it as a stand alone. Also check that the clips and o-rings on the SS bump shaft are all in place. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. If the voltage between the orange and black is not 12VAC, you need to replace the rectifier or the board. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. . The Filter Design Flow Rate is usually printed on the label, or can be found online. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The Aqua Rite is protected by a 20 amp mini ATO fuse located on the circuit board above the cell connector. Check the breaker inside the house, make sure its not tripped. So I filled pump basket with water and it happened again. We just has this pool installed year, and brought the motor inside the house. If thats not it, check the valves on the suction side (skimmer/main drain) to be sure they are not leaking air. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell. switch in the center. Hi Matt, my first guess would be an air leak on the suction side, most typically a loose pump lid (or no o-ring lube), or loose pipe that comes into the front of the pump (or no thread sealant on the threaded fitting), or sometimes a leaky suction side valve, or low water level, stuck skimmer weir Second guess would be a broken impeller, detached from the motor shaft. Yes, pool heaters do have a minimum flow requirement. It trips 20amp breaker after running 5 or 10 second. The pump need not be completely air tight, but has to pull more water than air! The display shows nothing as if it is not getting power. It can also be a loose pump lid allowing air to creep in around the o-ring. Also, DE filters need to be opened up and hosed down completely clean every 6-9 months, and then started up again with a full charge of DE powder. Backwashing or cleaning the pump basket is the usual fix. service center location, advanced Hope thats not the case. i just installed a vspnp hayward pump and when i flip the breaker on it only makes a clicking noise. Hello, Just bought a house with a pool in January. All pipes are 1.5 and solidly installed with primer and high quality glue for the PVC used. This just started. JavaScript is disabled. A wire connected to the terminal board may be loose or burnt. To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About. Also use a rag to clean the surfaces that mate on the pump body. The main panel feeds a Tork timer, which I dont use the timer, I disconnected the timer motor. hayward blue essence troubleshootingsolar panel for arlo essential spotlight camera hayward blue essence troubleshooting Menu everydrop water filter comparison. Motor is connected to 220 volts and each phase consume 3.8 amps. So yes it could be the filter, very clogged and in need of a deep cleaning, but probably not a filter mechanical issue. I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. Theres no sound, when we hit the power switch no power. I just purchased a brand new Hayward Super Pump 1.5HP for my pool that is being renovated. None of the indicating lights are on. I have a maxi-flo 2 and it just stopped working. I can turn the switch to low and it will start and run then switch to high. When pumps dont run for a long time, they are susceptible to rust forming in between the stator and rotor. Could be a problem with the centrifugal switch, located dead center on the rear of the motor, or the stationary switch, located beneath it, and contacting each other in the center. I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing Following this procedure will identify News Reporter Reveals On Live TV That Shes Been Secretly Recording We would like to show you a description here but the site wont allow us. Just hoping for some feed back and the name plate is missing from the Tristar Motor, to actually know the exact motor we have? Anything else to fiddle with or bad motor? It worked fine just prior to a filter cleaning. bought a SP2610x152s super pool pump 1.5 hp. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. Any suggestions or ideas as to why it is not producing chorine in regular mode? We have a Hayward Super Pump 260710 that is 1 hp.The pool was working fine when we opened it 1 week ago except after it would run for 15-20 mins the motor would trip the circuit breaker so we had an electrician replace the motor and check the electrical and that was fine; however, we cant get the pump primed. The pump is a Hayward Superpump SP1600X with a UST1102 motor. Any ideas? A pump that simply wont start is a frustrating problem. Loose wiring, or broken wires, or wires nearly touching each other, and arcing. 2. pump lid gasket or o-ring not lubed, or not positioned properly (superpump) One of the tads were not in the slot. New pump probably not a shaft seal problem, just loose clamp band or volute bolts. There should be no elbow after the flow switch. "@type": "Organization",
IF the shaft spins freely, and your motor hums and trips the breaker, first check the wiring connections on the incoming wires, nice and tight, and no bare wire touching anything except the terminal connector. But first, remove the fingers again, and soak the entire Nest Assembly in a bucket filled with pool filter cleaner, to dissolve oils and scale. Is the shaft spinning freely? Hi Julie, is the FLO error code on the heater? The pump may be reversible, able to accept either 115V or 230V, so the incoming voltage must match the set-up, +/- 10%. Hooked it up the same as the last motor and left the setting to 230 as that is what the last motor was set to run on. Is there a reset switch on the pump? We opened our pool today. The leak at the bottom of the pump, determine if its coming from the top of the pump and dripping down the sides, or if the leak is coming from directly under the pump, in the first case its usually the exit pipe threads are loose, and in the second case, its a leaking shaft seal or leaking drain plug, or sometimes a leaking volute o-ring, or the large o-ring between the seal plate and the pump housing. Hi Michelle, If the pump and motor are too large and powerful for your filter size, it would create this situation. If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. Glad that you replaced the sand, normally lasts 5-7 years on larger sand filters, but filters below 21 diameter need it more often, and very small filters 12-14, need it almost every season. We have tried switching outlets and that sometimes works. If any of these readings are outside limits, replace motor. Pump had been working fine, but this week started making a kind of rhythmic buzzing sound while running. Sometimes I am able to get it going by switching the breaker on/off several times, but most times I can hear the motor trying to start for a couple of seconds before it trips the breaker again and again. Hi, we just installed a new AquaRite unit and it has been running for 48 hrs The salt level is 3100 ppm (pool store also confirmed and tested the water, no issues detected with the water). Likewise, it could be any other obstruction after the pump (partially clogged pipes, small pipe size, partially closed return valves) all of which will produce higher than normal filter pressure. Or you can buy the bearings and seal, and with a set of bearing pullers you can replace your own. Hi David, yes! Loud screeching sound from 2 speed 1 HP pump, louder on faster speed. Clean Gasket (no bits of debris or de powder), 2. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. Click Here to View Replacement Aquarite Parts 25 This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. Hi Davy, Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. Do you think the motor is fried as a result of no water running thru? You will get much more visibility by. Thoughts? The other rectifier is rated as 18-33 VDC. Tried to vacuum. Also possible that the rubber is damaged, inspect closely for signs of wear while cleaning it. Hi, we had very heavy rain the other night and Im quite sure the rain at least briefly submerged the Hayward 2300 Variable speed pump I have. Disconnected the chlorination device, and direct connected it eliminating that. Try to spin the impeller with your fingers, or turn the motor shaft to check that it spins freely, or if not, put a wrench on the shaft and break the rust free. "
Thats unusual, shouldve fixed it. If the shaft is free turning, but the pump does not turn on, check power connections.